Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 234
Filtrar
2.
J Hosp Infect ; 130: 34-43, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36179793

RESUMO

BACKGROUND: Most COVID-19 outbreaks in nursing homes are explained by transmission of SARS-CoV-2 from nurses or visitors. METHODS AND RESULTS: We describe an outbreak with 64 of the 67 residents identified as COVID-19 cases within two weeks (34 in nursing block 1, 30 in nursing block 2), at least 32 of them had relevant symptoms of COVID-19. Thirteen of the residents' deaths were associated with COVID-19. In addition, 27 of approximately 60 staff members were identified as COVID-19 cases, 23 of them had relevant symptoms. In none of the samples from residents or staff was a mutation of SARS-CoV-2 detected. Quarantine of the residents was already in force at the beginning of the outbreak. A common source among the staff was considered to be unlikely because the two nursing home blocks had no staff rotation and the staff had to wear FFP2 masks during contact with residents. Three months after the outbreak the RNA of SARS-CoV-2 was detected on 14 of 39 sampled indoor surfaces of the air ventilation system with Ct values between 34.9 and 41.9, but only at the air supply in the corridor (11 of 24 samples) and the air overflow in the door between the corridor and the residents' rooms (three of 11 samples) but not at the air exhaust in the residents' bathrooms. CONCLUSIONS: The air ventilation system and an inversion weather situation three days before the first confirmed case may have enhanced viral spread inside the nursing home assuming that a common source with a high viral load had existed at the time of outbreak.


Assuntos
COVID-19 , Substâncias Explosivas , Humanos , COVID-19/epidemiologia , SARS-CoV-2 , Casas de Saúde , Surtos de Doenças
3.
J Hosp Infect ; 122: 140-147, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35077809

RESUMO

BACKGROUND: A sporicidal surface disinfection is recommended both for the outbreak and the endemic setting but a comparative evaluation on the efficacy of 'sporicidal' surface disinfectants using suspension tests and 4-field tests has not been performed. AIM: To determine the efficacy of five 'sporicidal' surface disinfectants (three ready-to-use wipes (A, B, E), two concentrates (C, D) based on peroxides or aldehydes against C. difficile spores. METHODS: The efficacy was determined under clean conditions using a suspension test and the 4-field test. Each test was performed in duplicate in two separate laboratories. Wipes were wrung to collect the solution for the suspension tests. RESULTS: Product A (peracetic acid; 5 min), product C (peracetic acid; 2% solution in 15 min or 1% solution in 30 min) and product D (peracetic acid; only 2% solution in 15 min) were effective with at least a 4 log10-reduction of C. difficile spores in suspension and on surfaces. Product B (hydrogen peroxide) was not effective in suspension (0.9 log10 after 15 min; 3.2 log10 after 1 h) and on surfaces (2.8 log10 after 15 and 60 min). Product E based on glutaraldehyde, (ethylendioxy)dimethanol and DDAC demonstrated 0.9 log10 after 4 h in suspension and 4.5 log10 after 4 h on surfaces. CONCLUSIONS: Not all surface disinfectants with a sporicidal claim were effective against C. difficile spores in standardized suspension tests and in the 4-field test. In clinical practice preference should be given to products that reliably pass the efficacy criteria of both types of tests.


Assuntos
Clostridioides difficile , Desinfetantes , Clostridioides , Desinfetantes/farmacologia , Humanos , Ácido Peracético/farmacologia , Esporos Bacterianos
4.
J Hosp Infect ; 116: 1-9, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34298033

RESUMO

BACKGROUND: Meningitis and spinal infections with Gram-negative bacteria after local injections for treatment of chronic back pain are rare. This study investigated an outbreak of Pseudomonas aeruginosa infections following computed tomography (CT)-guided spinal injections (SI). METHODS: A case was defined as a spinal infection or meningitis with P. aeruginosa after SI between 10th January and 1st March 2019 in the same outpatient clinic. Patients without microbiological evidence of P. aeruginosa but with a favourable response to antimicrobial therapy active against P. aeruginosa were defined as probable cases. FINDINGS: Twenty-eight of 297 patients receiving CT-guided SI during the study period developed meningitis or spinal infections. Medical records were available for 19 patients. In 15 patients, there was microbiological evidence of P. aeruginosa, and four patients were defined as probable cases. Two of 19 patients developed meningitis, while the remaining 17 patients developed spinal infections. The median time from SI to hospital admission was 8 days (interquartile range 2-23 days). Patients mainly presented with back pain (N=18; 95%), and rarely developed fever (N=3; 16%). Most patients required surgery (N=16; 84%). Seven patients (37%) relapsed and one patient died. Although the source of infection was not identified microbiologically, documented failures in asepsis when performing SI probably contributed to these infections. CONCLUSIONS: SI is generally considered safe, but non-adherence to asepsis can lead to deleterious effects. Spinal infections caused by P. aeruginosa are difficult to treat and have a high relapse rate.


Assuntos
Infecções por Pseudomonas , Antibacterianos/uso terapêutico , Surtos de Doenças , Humanos , Injeções Espinhais , Infecções por Pseudomonas/tratamento farmacológico , Infecções por Pseudomonas/epidemiologia , Pseudomonas aeruginosa , Tomografia Computadorizada por Raios X
6.
Placenta ; 98: 13-23, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33039027

RESUMO

INTRODUCTION: Globally, preterm birth has replaced congenital malformation as the major cause of perinatal mortality and morbidity. The reduced rate of congenital malformation was not achieved through a single biophysical or biochemical marker at a specific gestational age, but rather through a combination of clinical, biophysical and biochemical markers at different gestational ages. Since the aetiology of spontaneous preterm birth is also multifactorial, it is unlikely that a single biomarker test, at a specific gestational age will emerge as the definitive predictive test. METHODS: The Biomarkers Group of PREBIC, comprising clinicians, basic scientists and other experts in the field, with a particular interest in preterm birth have produced this commentary with short, medium and long-term aims: i) to alert clinicians to the advances that are being made in the prediction of spontaneous preterm birth; ii) to encourage clinicians and scientists to continue their efforts in this field, and not to be disheartened or nihilistic because of a perceived lack of progress and iii) to enable development of novel interventions that can reduce the mortality and morbidity associated with preterm birth. RESULTS: Using language that we hope is clear to practising clinicians, we have identified 11 Sections in which there exists the potential, feasibility and capability of technologies for candidate biomarkers in the prediction of spontaneous preterm birth and how current limitations to this research might be circumvented. DISCUSSION: The combination of biophysical, biochemical, immunological, microbiological, fetal cell, exosomal, or cell free RNA at different gestational ages, integrated as part of a multivariable predictor model may be necessary to advance our attempts to predict sPTL and PTB. This will require systems biological data using "omics" data and artificial intelligence/machine learning to manage the data appropriately. The ultimate goal is to reduce the mortality and morbidity associated with preterm birth.


Assuntos
Biomarcadores/sangue , Trabalho de Parto Prematuro/sangue , Feminino , Humanos , Gravidez
7.
Int J Hyg Environ Health ; 224: 113449, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31978723

RESUMO

Between August 2018 and June 2019, a river system in Germany that supplies a drinking water reservoir and is subject to the discharge from two sewage treatment plants was monitored for antibiotic residues via liquid chromatography-tandem mass spectrometry, antibiotic resistance genes (including blaNDM, blaVIM, blaOXA-48, blaKPC, blaGIM, blaSME, blaIMI, blaIMP, blaSPM, blaSIM, blaOXA-23, blaOXA-24, blaOXA-51, blaOXA-58, mcr) via qualitative real-time PCR and antibiotic-resistant bacteria [belonging to the ESKAPE-group (Enterococcus faecium, Staphyhlococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa and Enterobacter ssp.; with resistance against Carbapenemases, Cephalosporines and Colistin) and Escherichia coli] based on cultivation methods followed by a characterization via MALDI-TOF MS and susceptibility testing applying microdilution. Residues of macrolide antibiotics such as clarithromycin (up to 0.60 µg/L) and residues of sulfamethoxazole (up to 0.40 µg/L) and trimethoprim (up to 0.39 µg/L) were detected downstream of the sewage treatment plants. In addition, no antibiotic residues were detected upstream the respective sewage treatment plants, except for anhydroerythromycin (n = 1,

Assuntos
Água Potável/microbiologia , Farmacorresistência Bacteriana Múltipla/genética , Poluição da Água/estatística & dados numéricos , Monitoramento Ambiental , Alemanha , Testes de Sensibilidade Microbiana , Poluição da Água/análise
8.
Chemosphere ; 241: 125032, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31622887

RESUMO

The high use of antibiotics in human and veterinary medicine has led to a wide spread of antibiotics and antimicrobial resistance into the environment. In recent years, various studies have shown that antibiotic residues, resistant bacteria and resistance genes, occur in aquatic environments and that clinical wastewater seems to be a hot spot for the environmental spread of antibiotic resistance. Here a representative statistical analysis of various sampling points is presented, containing different proportions of clinically influenced wastewater. The statistical analysis contains the calculation of the odds ratios for any combination of antibiotics with resistant bacteria or resistance genes, respectively. The results were screened for an increased probability of detecting resistant bacteria, or resistance genes, with the simultaneous presence of antibiotic residues. Positive associated sets were then compared, with regards to the detected median concentration, at the investigated sampling points. All results show that the sampling points with the highest proportion of clinical wastewater always form a distinct cluster concerning resistance. The results shown in this study lead to the assumption that ciprofloxacin is a good indicator of the presence of multidrug resistant P. aeruginosa and extended spectrum ß-lactamase (ESBL)-producing Klebsiella spec., Enterobacter spec. and Citrobacter spec., as it positively relates with both parameters. Furthermore, a precise relationship between carbapenemase genes and meropenem, regarding the respective sampling sites, could be obtained. These results highlight the role of clinical wastewater for the dissemination and development of multidrug resistance.


Assuntos
Bactérias/efeitos dos fármacos , Farmacorresistência Bacteriana/genética , Águas Residuárias/microbiologia , Antibacterianos/farmacologia , Bactérias/genética , Proteínas de Bactérias/metabolismo , Ciprofloxacina/farmacologia , Humanos , Pseudomonas aeruginosa/efeitos dos fármacos , beta-Lactamases/metabolismo
9.
J Hosp Infect ; 103(1): 78-84, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31199936

RESUMO

BACKGROUND: Sporicidal surface disinfection is recommended to control transmission of Clostridium difficile in healthcare facilities. EN 17126 provides a method to determine the sporicidal activity in suspension and has been approved as a European standard. In addition, a sporicidal surface test has been proposed. AIM: To determine the interlaboratory reproducibility of a test method for evaluating the susceptibility of a C. difficile spore preparation to a biocidal formulation following the 4-field test (EN 16615 methodology). METHODS: Nine laboratories participated. C. difficile NCTC 13366 spores were used. Glutaraldehyde (1% and 6%; 15 min) and peracetic acid (PAA; 0.01% and 0.04%; 15 min) were used to determine the spores' susceptibility in suspension in triplicate. FINDINGS: One-percent glutaraldehyde revealed a mean decimal log10 reduction of 1.03 with variable results in the nine laboratories (0.37-1.49) and a reproducibility of 0.38. The effect of 6% glutaraldehyde was stronger (mean: 2.05; range: 0.96-4.29; reproducibility: 0.86). PAA revealed similar results. An exemplary biocidal formulation based on 5% PAA was used at 0.5% (non-effective concentration) and 4% (effective concentration) to determine the sporicidal efficacy (4-field test) under clean conditions in triplicate with a contact time of 15 min. When used at 0.5% it demonstrated an overall log10 reduction of 2.68 (range: 2.35-3.57) and at 4% of 4.61 (range: 3.82-5.71). The residual contamination on the three primarily uncontaminated test fields was <50 cfu/25 cm2 in one out of nine laboratories (0.5%) and in seven out of nine laboratories (4%). CONCLUSION: The interlaboratory reproducibility seems to be robust.


Assuntos
Clostridioides difficile/efeitos dos fármacos , Desinfetantes/farmacologia , Testes de Sensibilidade Microbiana/métodos , Esporos Bacterianos/efeitos dos fármacos , Glutaral/farmacologia , Variações Dependentes do Observador , Ácido Peracético/farmacologia , Reprodutibilidade dos Testes
10.
Int J Hyg Environ Health ; 222(4): 655-662, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30905579

RESUMO

Increasing isolation rates of resistant bacteria in the last years require identification of potential infection reservoirs in healthcare facilities. Especially the clinical wastewater network represents a potential source of antibiotic resistant bacteria. In this work, the siphons of the sanitary installations from 18 hospital rooms of two German hospitals were examined for antibiotic resistant bacteria and antibiotic residues including siphons of showers and washbasins and toilets in sanitary units of psychosomatic, haemato-oncological, and rehabilitation wards. In addition, in seven rooms of the haemato-oncological ward, the effect of 24 h of stagnation on the antibiotic concentrations and MDR (multi-drug-resistant) bacteria in biofilms was evaluated. Whereas no antibiotic residues were found in the psychosomatic ward, potential selective concentrations of piperacillin, meropenem and ciprofloxacin were detected at a rehabilitation ward and ciprofloxacin and trimethoprim were present at a haemato-oncology ward. Antibiotic resistant bacteria were isolated from the siphons of all wards, however in the psychosomatic ward, only one MDR strain with resistance to piperacillin, third generation cephalosporins and quinolones (3MRGN) was detected. In contrast, the other two wards yielded 11 carbapenemase producing MDR isolates and 15 3MRGN strains. The isolates from the haemato-oncological ward belonged mostly to two specific rare sequence types (ST) (P. aeruginosa ST823 and Enterobacter cloacae complex ST167). In conclusion, clinical wastewater systems represent a reservoir for multi-drug-resistant bacteria. Consequently, preventive and intervention measures should not start at the wastewater treatment in the treatment plant, but already in the immediate surroundings of the patient, in order to minimize the infection potential.


Assuntos
Bactérias/isolamento & purificação , Aparelho Sanitário/microbiologia , Farmacorresistência Bacteriana Múltipla , Hospitais , Águas Residuárias/microbiologia , Antibacterianos/análise , Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Bactérias/genética , Farmacorresistência Bacteriana Múltipla/genética , Monitoramento Ambiental , Genes Bacterianos
11.
J Hosp Infect ; 103(1): e88-e91, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30711531

RESUMO

The bactericidal activity of isopropanol was determined against Enterococcus faecium ATCC 6057, ST 796 (isopropanol-tolerant strain) and Enterococcus hirae ATCC 10541 (EN 13727). Isopropanol at 60% and 70% were effective (≥5.38 log10-reduction) in 15 s against all strains but 23% isopropanol was not (<0.99 log10-reduction in ≤15 min). Isopropanol at 70% was tested against E. faecium in the four-field test. Eight millilitres was not effective enough in 1 min (<5 log10-reduction), whilst 16 mL was effective (≥5.85 log10-reduction). Healthcare workers can be reassured that 60% and 70% isopropanol with an appropriate volume are effective against E. faecium.


Assuntos
2-Propanol/farmacologia , Desinfetantes/farmacologia , Tolerância a Medicamentos , Enterococcus faecium/efeitos dos fármacos , Viabilidade Microbiana/efeitos dos fármacos , Enterococcus faecium/fisiologia , Streptococcus faecium ATCC 9790/efeitos dos fármacos , Streptococcus faecium ATCC 9790/fisiologia , Humanos
12.
Int J Hyg Environ Health ; 222(3): 455-467, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30622005

RESUMO

Antibiotics represent one of the most important drug groups used in the management of bacterial infections in humans and animals. Due to the increasing problem of antibiotic resistance, assurance of the antibacterial effectiveness of these substances has moved into the focus of public health. The reduction in antibiotic residues in wastewater and the environment may play a decisive role in the development of increasing rates of antibiotic resistance. The present study examines the wastewater of 31 patient rooms of various German clinics for possible residues of antibiotics, as well as the wastewater of five private households as a reference. To the best of our knowledge, this study shows for the first time that in hospitals with high antibiotic consumption rates, residues of these drugs can be regularly detected in toilets, sink siphons and shower drains at concentrations ranging from 0.02 µg·L-1 to a maximum of 79 mg·L-1. After complete flushing of the wastewater siphons, antibiotics are no longer detectable, but after temporal stagnation, the concentration of the active substances in the water phases of respective siphons increases again, suggesting that antibiotics persist through the washing process in biofilms. This study demonstrates that clinical wastewater systems offer further possibilities for the optimization of antibiotic resistance surveillance.


Assuntos
Anti-Infecciosos/análise , Aparelho Sanitário , Equipamentos e Provisões Hospitalares , Águas Residuárias/análise , Poluentes Químicos da Água/análise , Monitoramento Ambiental , Alemanha , Hospitais , Habitação
13.
J Contam Hydrol ; 220: 128-135, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30591238

RESUMO

Identification of the nitrate sources that adversely impact groundwater quality is a necessary first step in the control of this major worldwide pollutant. The impact of nitrate leachate from urea-ammonium nitrate (UAN) (50% urea-N, 25% ammonium-N, 25% nitrate-N) fertilizer, whose use has increased dramatically in the last three decades largely because it can be applied through sprinkler irrigation systems to corn in all growth stages, is investigated. The dual isotopes δ15NNO3 and δ18ONO3 were measured in groundwater samples from 39 irrigation wells in two intensively sprinkler-irrigated, corn-growing areas of Nebraska with nitrate-contaminated (N > 10 mg/L) groundwater and documented UAN use to ascertain whether nitrified ammonia and nitrate fertilizers can be distinguished in the High Plains aquifer. The areas, which are highly vulnerable to nitrate leaching and differ only in the composition and thickness of their unsaturated zones, are uniquely suited to provide scientific evidence of the feasibility of identifying nitrate fertilizer leachate in groundwater and thereby add significantly to the small body of existing and inconclusive data. The dual isotope method (DIM) results indicate that the nitrate contamination in 38 wells is mostly nitrified ammonium fertilizer. Most importantly, nitrate fertilizer from UAN was not identified isotopically in groundwater beneath almost all fields with documented heavy UAN use. This could be a potentially valuable finding for fertilizer management or it could convey limitations on the appropriateness of the DIM for nitrate fertilizer source identification in groundwater. Slightly enriched δ15NNO3 values in a few wells coincide with the practice of wintering cattle on corn stubble, which reportedly occurred more frequently in one focus area. The absence of natural soil-N leachates and denitrification in groundwater enabled an apparently reliable identification of manure leachates in both areas.


Assuntos
Água Subterrânea , Poluentes Químicos da Água , Animais , Bovinos , Produtos Agrícolas , Monitoramento Ambiental , Fertilizantes , Nitratos , Isótopos de Nitrogênio
14.
Water Res ; 149: 21-34, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30445393

RESUMO

Wastewater treatment plants (WWTPs) have been identified as confirmed but until today underestimated sources of Legionella, playing an important role in local and community cases and outbreaks of Legionnaires' disease. In general, aerobic biological systems provide an optimum environment for the growth of Legionella due to high organic nitrogen and oxygen concentrations, ideal temperatures and the presence of protozoa. However, few studies have investigated the occurrence of Legionella in WWTPs, and many questions in regards to the interacting factors that promote the proliferation and persistence of Legionella in these treatment systems are still unanswered. This critical review summarizes the current knowledge about Legionella in municipal and industrial WWTPs, the conditions that might support their growth, as well as control strategies that have been applied. Furthermore, an overview of current quantification methods, guidelines and health risks associated with Legionella in reclaimed wastewater is also discussed in depth. A better understanding of the conditions promoting the occurrence of Legionella in WWTPs will contribute to the development of improved wastewater treatment technologies and/or innovative mitigation approaches to minimize future Legionella outbreaks.


Assuntos
Legionella , Doença dos Legionários , Humanos , Temperatura , Águas Residuárias
16.
J Hosp Infect ; 99(2): 208-217, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29203445

RESUMO

BACKGROUND: The current increase in nosocomial infections caused by vancomycin-resistant enterococci (VRE) warrants improvement of detection methods and hygiene measures. Knowledge of the local epidemiology is important for monitoring compliance of medical personnel with hygiene measures. AIM: To evaluate semi-automated repetitive element palindromic polymerase chain reaction (rep-PCR) for rapid molecular typing of VRE. METHODS: Primary VRE isolates were collected during an observation period of one year and retrospectively typed by rep-PCR. Molecular typing was performed on isolates from two departments with elevated VRE rates and patients with increased risk for systemic VRE infections. Typing results were correlated with temporal and spatial information on patient moves, VRE laboratory results and multi-locus sequence typing (MLST). FINDINGS: Approximately 70% of VRE isolates within a department could be assigned to similarity clusters. Spread of VRE was limited to the individual departments. There was no evidence for spread of endemic VRE strains within the geographical catchment area of the hospital. Our results demonstrate the utility of rep-PCR typing on a department level. However, a Diversilab® threshold of ≥98% had to be applied to claim similarity, and suspected transmissions needed to be confirmed by vanA/B genotyping and compiled information on spatial and temporal patient contact. MLST verified the findings. CONCLUSION: Spread of predominantly detected vancomycin-resistant Enterococcus faecium was limited to the department level with no evidence for wider dissemination within the hospital. Well-standardized and validated (semi-)automated rep-PCR systems are useful for rapid detection of possible VRE transmission. However, suspected transmissions need to be confirmed by clinical and microbiological parameters.


Assuntos
Infecção Hospitalar/epidemiologia , Enterococcus faecium/isolamento & purificação , Infecções por Bactérias Gram-Positivas/epidemiologia , Epidemiologia Molecular/métodos , Tipagem Molecular/métodos , Reação em Cadeia da Polimerase/métodos , Enterococos Resistentes à Vancomicina/isolamento & purificação , Infecção Hospitalar/microbiologia , Infecção Hospitalar/transmissão , DNA Bacteriano/genética , Enterococcus faecium/classificação , Enterococcus faecium/genética , Monitoramento Epidemiológico , Infecções por Bactérias Gram-Positivas/microbiologia , Infecções por Bactérias Gram-Positivas/transmissão , Departamentos Hospitalares , Humanos , Epidemiologia Molecular/normas , Tipagem Molecular/normas , Reação em Cadeia da Polimerase/normas , Sequências Repetitivas de Ácido Nucleico , Estudos Retrospectivos , Análise Espaço-Temporal , Enterococos Resistentes à Vancomicina/classificação , Enterococos Resistentes à Vancomicina/genética
17.
Acta Anaesthesiol Scand ; 61(1): 91-98, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27778324

RESUMO

BACKGROUND & OBJECTIVES: Most anesthesiologists use the injection of a test dose of local anesthetic in order to evaluate the final needle tip position. Thus, the intraneural injection of a full dose can be avoided. The aim of this study was to analyze whether an intraneural injection of a test dose of bupivacaine could trigger histological changes. METHODS: Intraneural injections under direct vision were performed in 40 brachial plexus nerves in seven anesthetized pigs. Tibial nerves served as positive and negative controls. Two milliliter of bupivacaine 0.5% was injected in three nerves on the left brachial plexus. For control of local anesthetic's toxicity Ringer's solution was applied intraneurally on the right side. After maintaining 48 h of general anesthesia, the nerves were resected. The specimens were processed for histological examination and assessed for inflammation (hematoxylin and eosin stain, CD68-immunohistochemistry) and myelin damage (Kluver-Barrera stain). The degree of nerve injury was rated on a scale from 0 (no injury) to 4 (severe injury). RESULTS: Statistical analysis showed no significant differences between the bupivacaine group [median (interquartile range) 1 (1-1.5)] and the Ringer's solution group [1 (0.5-2) P = 0.772]. Mild myelin alteration was found in 12.5% of all specimens following intraneural injection, irrespective of the applied substance. CONCLUSIONS: "In our experimental study, intraneural injection of 2 ml of bupivacaine or Ringer's solution showed comparable mild inflammation. Nevertheless, inflammation can only be prevented by strictly avoiding nerve perforation followed by intraneural injection, as mechanical nerve perforation is a key factor for evolving inflammation.


Assuntos
Anestésicos Locais/farmacologia , Bupivacaína/farmacologia , Bloqueio Nervoso , Nervos Periféricos/efeitos dos fármacos , Anestésicos Locais/administração & dosagem , Animais , Feminino , Injeções , Nervos Periféricos/patologia , Suínos
18.
Water Sci Technol ; 74(4): 816-23, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27533856

RESUMO

A community-wide outbreak of Legionnaire's disease occurred in Warstein, Germany, in August 2013. The epidemic strain, Legionella pneumophila Serogruppe 1, was isolated from an industrial wastewater stream entering the municipal wastewater treatment plant (WWTP) in Wartein, the WWTP itself, the river Wäster and air/water samples from an industrial cooling system 3 km downstream of the WWTP. The present study investigated the effect of physical-chemical disinfection methods on the reduction of the concentration of Legionella in the biological treatment and in the treated effluent entering the river Wäster. Additionally, to gain insight into the factors that promote the growth of Legionella in biological systems, growth experiments were made with different substrates and temperatures. The dosage rates of silver micro-particles, hydrogen peroxide, chlorine dioxide and ozone and pH stress to the activated sludge were not able to decrease the number of culturable Legionella spp. in the effluent. Nevertheless, the UV treatment of secondary treated effluent reduced Legionella spp. on average by 1.6-3.4 log units. Laboratory-scale experiments and full-scale measurements suggested that the aerobic treatment of warm wastewater (30-35 °C) rich in organic nitrogen (protein) is a possible source of Legionella infection.


Assuntos
Compostos Clorados/farmacologia , Desinfetantes/farmacologia , Desinfecção/métodos , Legionella/efeitos dos fármacos , Óxidos/farmacologia , Ozônio/farmacologia , Águas Residuárias/microbiologia , Desinfetantes/química , Alemanha , Legionella/fisiologia , Esgotos/microbiologia , Microbiologia da Água
19.
Technol Health Care ; 24(3): 309-15, 2016 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-26835724

RESUMO

BACKGROUND: The intraoperative application of focused transthoracic echocardiography (TTE) is often considered to be restricted. Echocardiography with pocket-sized hand held ultrasound systems has been shown to be feasible in various settings. OBJECTIVE: The aim of this study was to investigate the feasibility of the intraoperative application of pocket-sized echocardiography and the comparison of its imaging quality and diagnostic reliability and variability with a standard ultrasound system. METHODS: After written informed consent, TTE was performed on 40 anaesthetised general, vascular, visceral, thoracic surgical and orthopaedic patients according to the FATE protocol: first, with a pocket-sized and second, with a high-end ultrasound system randomly by two anaesthetists. Imaging quality of four basic and three additional FATE views was rated on an established scale from 1 (impossible) to 5 (perfect). Successful TTE was defined, if one basic FATE views would be rated as grade 4 or 5 or alternatively two views as grade 3. Pathologic findings by both ultrasound devices were documented and imaging quality and pathologic findings were compared. RESULTS: All 40 patients presented acceptable imaging quality, resulting in a success rate of 1.0 (97.5%-CI 0.91-1, p= 0.015). The individual imaging ratings of each view were significantly lower with the pocket-sized system, but still showed acceptable imaging quality. With the high-end device more pathologic findings were detected (107 vs. 87), but none of the relevant or severe pathologies were overseen with the hand-held device. CONCLUSION: The application of a pocket-sized echocardiography device for focused intraoperative TTE is feasible and can appropriate be used for the initial evaluation of relevant pathologies in the operating theatre.


Assuntos
Anestesiologistas , Ecocardiografia/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...